A-Series Internal Pilot with Threaded Connections
A-Series Internal Pilot with Threaded Connections
Models
AAP: Cast Iron
ACP: Cast Steel
ASSP: Stainless Steel
- API 520 & 614 Approved
- Chatter-free operation
- Mount in any position
- Suitable for continuous duty
Size Range: 2.5″ and 3″
Pressures: 50 – 500 psi
Flow Rate: 150 – 350 gpm
INSTALLATION, MAINTENANCE & OPERATION
Installation
Fulflo valves can be mounted in any position. A tee may be inserted in the pump discharge line to mount the valve. The pipelines carrying the heavy valves must be well supported and overhung weights avoided. The correct size of the valve must be used, preferably equal to the size of the pipeline to which they are connected. Threaded valves (AAD and ACD) may be threaded into pipe nipples. Overhung weights on threads should be avoided. The outlet of the valve should be piped to the supply tank unless specific applications call for alternate piping of return lines. Care must be taken to have the discharge well below the oil level in the tank to prevent air entrainment and erratic operation.
Setting Valves
The valve may be set with a hydraulic hand pump for cracking pressure. If a test stand is available, the valve should be connected to the discharge header with the pump bypass open, and the bypass gradually closed until the desired pressure registers on the gauge. For Pilot Operated valves, adjust the valve adjusting screw until approximately 5-7 GPM is flowing through the valve, at that point, the main piston will open, and then the valve will be considered at the setpoint, then the lock adjusting screw. If a valve is required to bypass a given amount of fluid at a given pressure, a test stand having a flow meter in the a pump discharge line must be available. With a valve adjusting for cracking pressure as above, continue closing the bypass until the required flow registers on the flow meter and observe pressure. Readjust pressure, if necessary, to obtain the desired pressure at the desired flow.
Maintenance & Operation
Fulflo valves provide reliable “chatter-free” operation when the system is free of abrasives and foreign matter. Continuous filtration of the liquid used is strongly recommended.